top of page
Search

ISO 12944: what GALVANOL thickness each project needs

GALVANOL IBERIA SL
1 hour ago
2 min read

The ISO 12944 standard classifies environments by corrosivity (C1 to CX) and sets how many years a paint system must last according to its thickness. This guide summarises the results of GALVANOL tests according to ISO 12944-6:2018, carried out in an ENAC-accredited laboratory, so you know what thickness to apply on your project.

1. Identify your project's environment

  • C2 (low): unheated buildings, warehouses, rural structures.

  • C3 (medium): railings, fences and urban structures; coastal areas with low salinity.

  • C4 (high): industrial areas, chemical plants, bridges, moderate seafront.

  • C5 (very high): ports, marine structures, industry with high humidity and aggressive atmosphere.

  • CX (extreme): offshore and extreme industrial areas.

2. Choose the GALVANOL thickness (can and pail)

Test results according to ISO 12944-6:2018, on a blasted surface (roughness 20–25 µm). Durability: L = up to 7 years, M = 7–15, H = 15–25, VH = more than 25 years.

  • ≥ 60 µm (1 coat): more than 25 years in C1 and C2; 15–25 years in C3; 7–15 years in C4; up to 7 years in C5.

  • ≥ 80 µm (1–2 coats): more than 25 years in C3; 15–25 years in C4; 7–15 years in C5.

  • ≥ 121 µm (1–2 coats): more than 25 years in C4; 15–25 years in C5.

  • ≥ 130 µm (2 coats or more): more than 25 years in C5.

CX environment (ISO 12944-9:2018): 2-coat system with a minimum of 150 µm dry, about 700 g/m² theoretical consumption, and up to 200 µm in 3–4 coats.

3. Work out the kilos

GALVANOL covers about 250–280 g/m² per coat for 40–60 µm dry. Do not exceed 200 µm total dry thickness. To repair hot-dip galvanizing, ISO 1461 requires at least 100 µm on the repaired area (unless otherwise agreed with the customer); with GALVANOL that means about 490 g/m² (105 µm).

Use the How much GALVANOL do I need? calculator with your surface area and number of coats.

Tip: durability depends as much on thickness as on surface preparation. Measure the dry thickness with a coating gauge whenever the project requires it.

Have a project? We are the manufacturer: write to info@galvanol.eu for quotes, samples or technical advice. Technical data sheets and safety data sheets are available in Products.

 
 
 

Comments


Stay informed, subscribe to our newsletter

Thanks for subscribing!