Cold vs hot-dip galvanizing: differences and when to use each
Galvanizing means protecting steel with zinc. Zinc corrodes much more slowly than steel and, if a pore or scratch appears, it sacrifices itself so the steel doesn't rust. That protection can be achieved in two very different ways: by dipping the part in molten zinc or by applying a zinc-rich coating as if it were a paint.
Hot-dip galvanizing
The part is chemically cleaned and dipped in a bath of molten zinc at about 450 °C. The zinc reacts with the steel and forms zinc-iron alloy layers metallurgically bonded to the steel, with an outer layer of pure zinc. The reference standard in Europe is ISO 1461.
Advantages: a coating that is highly resistant to impacts and abrasion, with uniform thickness and great durability.
Limitations: the part has to be taken to the galvanizing plant, its size is limited by the bath, it can't be done on site, and any later cutting, drilling or welding is left unprotected.
Cold galvanizing
It is a coating with a very high proportion of zinc dust, applied by brush, roller, spray gun or aerosol. To protect like hot-dip galvanizing, the zinc must be in electrical contact with the steel and between its particles: that is why the zinc content in the dry film matters so much. GALVANOL has a minimum of 96%.
Advantages: it is applied on site or in the workshop, with no limit on part size, on structures already assembled and in maintenance. It provides active cathodic protection and barrier protection.
Limitations: it requires good surface preparation and control of dry film thickness; against heavy impacts it is less resistant than hot-dip galvanizing.
When to use each one?
New part that fits in the bath and will not be modified: hot-dip galvanizing.
Repairing hot-dip galvanizing damaged by impacts, cuts, drilling or welding: cold galvanizing, according to ISO 1461 and ASTM A780.
Large or already assembled structures (industrial buildings, solar parks, bridges, towers): cold galvanizing on site.
Maintenance of aged or rusty galvanized steel: cold galvanizing after surface preparation.
Site-welded joints of galvanized elements: cold galvanizing over the cleaned weld.
The two systems don't compete: they complement each other. In a well-executed project, the usual approach is to hot-dip galvanize whatever can be galvanized and protect with cold galvanizing everything that is cut, welded or damaged afterwards.
Quick comparison
How it is applied: GALVANOL by brush, roller, spray gun or aerosol, in the workshop or on site; hot-dip galvanizing by immersion in molten zinc (about 450 °C) at a plant.
Part size: cold: no limit; hot-dip: limited by the size of the bath.
Site welds and drill holes: cold: treated on the spot; hot-dip: they have to be repaired afterwards.
Heat distortion: cold: none; hot-dip: possible on thin sheet.
Thickness: cold: about 40 µm per coat and 2–3 coats (maximum 200 µm); hot-dip: depending on the part thickness (ISO 1461).
Does it need CE marking?
In the EU, CE marking is only mandatory for construction products covered by a harmonised standard or a European Technical Assessment (Regulation (EU) 305/2011). Anti-corrosion paints for steel have no harmonised standard, so they don't need it. The exception is reinforcement protection in concrete repair, regulated by the harmonised standard EN 1504-7.
Not sure which system your project needs? Write to us at info@galvanol.eu or see the technical data sheets at Products.



Comments